How to Properly use a Gel Clot Activator Tube?

How to Properly use a Gel Clot Activator Tube?

In the world of medical diagnostics, gel clot activator tubes play a crucial role in ensuring accurate and reliable test results. These tubes are designed to accelerate the clotting process, separating serum from blood cells efficiently. Whether you’re a healthcare professional or a lab technician, understanding how to use these tubes correctly is essential. This comprehensive guide will walk you through everything you need to know about gel clot activator tubes, from their purpose to step-by-step instructions for proper usage.

What is a Gel Clot Activator Tube?

A gel clot activator tube is a specialized blood collection tube that contains a gel separator and clot activators. The gel separator forms a barrier between the serum and the clot during centrifugation, while the clot activators speed up the clotting process. These tubes are commonly used in clinical laboratories for tests that require serum, such as chemistry panels, hormone assays, and drug level monitoring.

Custom collecting tube with gel + clot activator
  • Clot Activator – Enhances blood clotting for faster serum separation.
  • Gel Barrier – Prevents contamination by separating serum from blood cells.
  • Vacuum System – Ensures accurate blood draw volume.

For a detailed overview of clot activator tubes, visit Clot Activator Coagulant Tube.

Proper Usage of Gel Clot Activator Tubes

Step-by-Step Guide

Preparation:

  • Ensure that the gel clot activator tube is within its expiration date and has not been damaged.
  • Gather all necessary materials, including gloves, a tourniquet, and a needle.

    Patient Preparation:

    • Explain the procedure to the patient to alleviate any anxiety.
    • Position the patient comfortably, ensuring the arm is extended and supported.

      Venipuncture:

      • Apply a tourniquet above the intended puncture site to engorge the vein.
      • Clean the puncture site with an antiseptic wipe and allow it to dry.
      • Insert the needle at a 15-30 degree angle into the vein, ensuring proper blood flow.

        Filling the Tube:

        • Once blood flow is established, insert the gel clot activator tube into the holder.
        • Allow the tube to fill to the appropriate volume without forcing blood into the tube.
        • Gently invert the tube 5-10 times to mix the blood with the clot activator.

          Post-Collection:

          • Remove the tourniquet and needle carefully.
          • Apply pressure to the puncture site with a cotton ball or gauze.
          • Label the tube with the patient’s information and the date of collection.

            Centrifugation:

            • Allow the tube to sit at room temperature for 30 minutes to 1 hour to facilitate clot formation.
            • Centrifuge the tube according to the manufacturer’s instructions, typically at 3000 RPM for 10 minutes.

              Separation:

              • After centrifugation, the gel will form a barrier between the serum and the cellular components.
              • Carefully transfer the serum for testing, ensuring not to disturb the gel layer.

              Components of a Gel Clot Activator Tube

              Understanding the components of a gel clot activator tube is key to using it effectively:

              1. Tube Material: Made of high-quality plastic or glass to ensure durability and safety.
              2. Gel Separator: A thixotropic gel that moves during centrifugation to form a stable barrier.
              3. Clot Activators: Substances like silica particles or thrombin that promote rapid clotting.
              4. Vacuum System: Ensures precise blood collection volume.

              Explore our range of gel clot activator tubes in different sizes, such as 6ml, 7ml, 8ml, 9ml, and 10ml.

              Final Thoughts

              Proper handling of a gel clot activator tube is essential for accurate lab results. From correct blood collection to centrifugation, following the right procedures minimizes errors and ensures high-quality serum samples.

              For the best gel clot activator tubes, check out Siny Medical or contact them here.

              For international sourcing, visit Siny Medical’s Made-in-China page.

              FAQs Gel Clot Activator Tubes

              1. What is the purpose of a gel clot activator tube?

              It accelerates blood clotting and separates serum from blood cells for accurate laboratory testing.

              2. How long should blood clot before centrifugation?

              Allow 15-30 minutes at room temperature before centrifuging.

              3. Can I reuse a gel clot activator tube?

              No, these tubes are single-use only to maintain sterility and accuracy.

              4. Where can I buy high-quality gel clot activator tubes?

              You can purchase premium clot activator tubes from Siny Medical.

              Best Selling Products
              Send Your Inquiry