| Item | Specification |
|---|---|
| Product Name | Total Bacteria Test Tube |
| Volume | 9ml |
| Test Principle | Extinction Dilution Method |
| Sample Type | Water Samples / Soil Leachate |
| Culture Temperature | 28±2°C |
| Culture Period | 5–7 Days |
| Packaging | 8 Tubes/Box; 1200 Tubes/Carton |
Total bacterial count in water provides useful information about the general bacterial level in a water sample. It can support routine monitoring, water-quality analysis, and investigation of microbial changes in different water systems.
The Siny Medical Total Bacteria Test Tube provides a culture-based method for detecting and estimating total bacteria in compatible samples. Each tube contains 9ml of prepared culture medium.
The test uses an extinction dilution method. A representative sample is transferred through a series of test tubes for step-by-step dilution. After incubation, the positive reactions and dilution levels are used to determine the bacterial growth level.
This method is suitable for drinking water, groundwater, industrial circulating water, soil leachate, and other compatible samples.
Bacterial populations can change as water moves through storage, treatment, circulation, and industrial systems.
For this reason, monitoring total bacteria can help users evaluate microbial conditions and identify changes that may require further investigation.
The Total Bacteria Test Tube can support applications such as:
The test focuses on bacterial growth under the defined culture conditions.
It does not identify individual bacterial species. Therefore, a targeted microbiological test may still be required when a specific microorganism needs to be identified.
The Total Bacteria Test Tube uses the extinction dilution method.
First, collect a representative sample using a sterile container. If a solid sample needs to be tested, prepare a suitable leachate before testing.
Next, arrange the test tubes in sequence and label them according to the required dilution levels.
Using a sterile syringe, transfer 1ml of the representative sample into the first test tube. The instructions recommend an 18G needle for sample transfer.
Mix the first tube thoroughly. Then use another sterile syringe to transfer 1ml from the first tube into the second tube.
Repeat the process through the required dilution series.
Each dilution step reduces the bacterial concentration in the following tube. After preparation, place the tubes under the specified culture conditions.
The final bacterial level is evaluated according to the positive reactions and corresponding dilution levels.
After inoculation and dilution, place the prepared test tubes in a constant-temperature incubator.
The specified culture conditions are:
Avoid unnecessary movement or tilting during incubation.
The original culture medium is clear and red.
A positive result occurs when the red liquid changes to yellow. This indicates bacterial growth under the specified test conditions.
A negative result occurs when the medium remains in its original clear red state without an obvious color change.
Observe the tubes during the culture period and record the final result after incubation.
The Total Bacteria Test Tube is not limited to a simple positive or negative observation.
Its extinction dilution method uses a series of progressively diluted samples.
After incubation, record which tubes show a positive reaction. Then arrange the results according to the corresponding dilution levels.
If positive reactions continue into higher dilution levels, this indicates a relatively higher bacterial content in the original sample.
The positive tube pattern and dilution level can then be used according to the specified calculation procedure to determine the bacterial growth index and level.
This is different from estimating bacterial concentration based only on how strong a color change appears.
For this reason, users should follow the defined dilution sequence and result-calculation method rather than creating a concentration estimate from visual intensity alone.
Correct sample preparation is important for bacterial testing.
Use a sterile container when collecting water samples. This helps reduce the risk of introducing microorganisms from outside the original sample.
For solid samples, prepare a leachate before testing.
If the water sample is turbid, the product instructions allow filtration through a 0.45μm membrane to remove interfering impurities before testing.
Sterile technique should continue throughout sample transfer and dilution.
During each dilution step, mix the test tube thoroughly for approximately 1–2 minutes before transferring the next 1ml sample.
The test tubes provide a vacuum, oxygen-free condition for culture. Follow the supplied operating procedure to maintain the required environment during testing.
Total bacteria, iron-oxidizing bacteria, and sulfate-reducing bacteria represent different testing targets.
A Total Bacteria Test Tube is used to evaluate general bacterial content under its specified culture conditions.
An Iron-Oxidizing Bacteria (IOB) Test Tube specifically targets iron bacteria.
A Sulfate-Reducing Bacteria (SRB) Test Tube targets sulfate-reducing bacteria.
Although these products use similar dilution-based testing workflows, their culture media and positive reactions differ.
Therefore, the three test tubes should not be treated as interchangeable.
Start by identifying the microbial parameter that needs to be monitored. Then select the corresponding bacterial test tube.
When selecting a bacterial detection tube, begin with the target microorganism or bacterial group.
For total bacterial count in water, choose a test tube intended for total bacteria rather than an IOB or SRB-specific product.
Next, confirm the testing conditions and sample requirements.
Important factors include:
Storage is also important before testing.
Keep unopened Total Bacteria Test Tubes in a cool, dry place protected from light at 4–25°C. The specified unopened shelf life is 2 years. Once opened, use the product within 2 weeks according to the instructions.
Siny Medical can supply Total Bacteria Test Tubes for water-quality, environmental, and industrial monitoring requirements.
Total bacterial count provides information about bacterial content detected under a defined culture method. It can support microbial monitoring of compatible water samples.
The test uses an extinction dilution method. Samples are progressively diluted through a series of test tubes. Positive reactions and dilution levels are then used to evaluate bacterial content.
Each Total Bacteria Test Tube contains 9ml of culture medium.
The instructions specify transferring 1ml of representative sample at each dilution step.
The specified incubation temperature is 28±2°C. The tubes should remain protected from light during culture.
The standard culture period is 5–7 days. Depending on the actual testing situation, observation may be extended to 10 days.
The culture medium starts as a clear red liquid. A change from red to yellow indicates a positive bacterial growth reaction under the specified test conditions.
Store the tubes at 4–25°C in a cool, dry place protected from light. The unopened shelf life is 2 years. After opening, use the product within 2 weeks.
The Siny Medical Total Bacteria Test Tube provides a practical culture-based method for detecting and estimating bacterial content in compatible water samples.
Its 9ml prepared medium supports an extinction dilution workflow. After incubation at 28±2°C, users evaluate the specified color reaction together with the dilution level to determine bacterial growth.
The product can support oilfield water monitoring, environmental monitoring, water-quality analysis, industrial water treatment, and groundwater applications.
Siny Medical can also discuss bulk supply, labeling, packaging, and other confirmed order requirements.
Contact Siny Medical for Total Bacteria Test Tube specifications, bulk pricing, or a quotation.