| Item | Specification |
|---|---|
| Product Name | Total General Bacteria Test Tube |
| Volume | 9ml |
| Test Principle | Extinction Dilution Method |
| Sample Type | Water Samples / Soil Leachate |
| Culture Temperature | 28±2°C |
| Culture Period | 5–7 Days |
| Packaging | 8 Tubes/Box; 1200 Tubes/Carton |
The Total General Bacteria Test Tube is a culture-based detection tube for testing total bacteria in compatible water and environmental samples. It provides a practical method for evaluating bacterial content through step-by-step sample dilution and culture.
Each Siny Medical test tube contains 9ml of prepared culture medium. The test uses the extinction dilution method. After inoculation and incubation, users identify positive tubes by the specified color reaction. The positive results and corresponding dilution levels are then used to evaluate bacterial content.
The product can be used with drinking water, groundwater, industrial circulating water, soil leachate, and other compatible samples. It is suitable for environmental monitoring, water-quality analysis, industrial water treatment, groundwater monitoring, and related applications.
The Total General Bacteria Test Tube uses a serial dilution process.
A representative sample is first introduced into the first tube. After thorough mixing, a defined amount is transferred into the next tube. This process continues through the required dilution series.
As the process continues, each tube represents a progressively higher dilution of the original sample.
The prepared tubes are then incubated under specified conditions. After incubation, the user records which tubes show a positive bacterial reaction.
The combination of positive reactions and dilution levels provides the basis for evaluating bacterial content in the original sample.
This approach provides more information than simply observing whether bacteria are present in a single tube.
Correct sample handling and sterile technique are important throughout the test.
Collect the water sample in a sterile container to reduce the risk of external microbial contamination.
For solid samples, prepare an appropriate leachate before testing.
If the sample contains interfering suspended material, follow the supplied testing procedure for sample preparation before inoculation.
Arrange the Total General Bacteria Test Tubes in sequence and number them according to the planned dilution levels.
Multiple groups can also be prepared when parallel testing is required.
Use a sterile syringe to collect 1ml of representative sample.
The product instructions recommend an 18G needle for sample transfer.
Inject the sample into the first test tube and mix thoroughly.
Use another sterile syringe to transfer 1ml from the first tube into the second tube.
Mix the second tube thoroughly before continuing.
Repeat this process through the required dilution series. Each dilution step should be mixed thoroughly for approximately 1–2 minutes before the next transfer.
Place the prepared tubes in a constant-temperature incubator.
Culture them at 28±2°C, protected from light, for 5–7 days.
When required by the testing situation, the culture period may be extended to 10 days.
Avoid unnecessary movement or tilting of the tubes during incubation.
The unused culture medium has a clear red appearance.
After incubation, observe each tube and record the result.
A change from red to yellow indicates bacterial growth under the specified test conditions.
If positive reactions continue into higher dilution levels, the original sample has a relatively higher bacterial content.
The dilution series and number of positive tubes can then be used according to the specified calculation procedure to determine the bacterial growth level.
If the medium remains in its original clear red state without an obvious color change, bacteria were not detected under the conditions of that test.
Result interpretation should always consider the complete dilution series rather than the color intensity of a single tube.
Total General Bacteria testing can support microbial monitoring across several water-related applications.
Typical applications include:
The test is particularly useful when users need to monitor changes in general bacterial content rather than target one specific bacterial group.
For routine monitoring programs, using the same sampling, dilution, incubation, and interpretation procedure also helps improve consistency between different testing periods.
Selecting the correct bacterial test tube depends on the microorganism or bacterial group being investigated.
A Total General Bacteria Test Tube evaluates general bacterial content under its defined culture conditions.
An Iron-Oxidizing Bacteria (IOB) Test Tube is designed specifically for iron bacteria. Its culture medium and positive reaction differ from those of the Total General Bacteria Test Tube.
A Sulfate-Reducing Bacteria (SRB) Test Tube targets sulfate-reducing bacteria and uses its own corresponding culture and result criteria.
Therefore, TGB, IOB, and SRB test tubes are not interchangeable.
For general bacterial monitoring, select the Total General Bacteria Test Tube. When a specific bacterial group needs to be investigated, use the corresponding targeted detection tube.
Store unopened Total General Bacteria Test Tubes at 4–25°C in a cool, dry place protected from light.
The specified shelf life is 2 years when unopened. After opening, use the product within 2 weeks according to the supplied instructions.
The test tubes provide a vacuum, oxygen-free condition for culture. Follow the specified operating procedure during testing to maintain the required environment.
Sterile technique is also important throughout sample collection, inoculation, and dilution. External microbial contamination can interfere with the final result.
Siny Medical can provide Total General Bacteria Test Tubes for laboratory, environmental, and industrial water-monitoring requirements.
It is a culture-based test tube used to detect and evaluate total bacterial content in compatible water and environmental samples.
Each test tube contains 9ml of prepared culture medium.
The product uses the extinction dilution method. The sample is progressively diluted through a series of tubes, followed by incubation and observation of positive reactions.
The original medium is clear and red. A change from red to yellow indicates a positive bacterial reaction under the specified test conditions.
The three products target different bacterial groups and use different culture media and positive-result criteria. TGB is intended for general bacterial monitoring, while IOB and SRB tubes target iron bacteria and sulfate-reducing bacteria respectively.
The Siny Medical Total General Bacteria Test Tube combines prepared culture medium with an extinction dilution testing method for bacterial monitoring.
Its 9ml configuration supports step-by-step sample dilution. After incubation at 28±2°C, a red-to-yellow color change identifies positive bacterial growth under the specified test conditions.
The product can support water-quality analysis, environmental monitoring, industrial water treatment, oilfield water monitoring, and related applications.
Siny Medical can also support bulk supply, packaging, labeling, and confirmed OEM/ODM requirements.
Contact Siny Medical for Total General Bacteria Test Tube specifications, pricing, samples, or bulk-order information.
Copyright © 2026 | Ningbo Siny Medical Technology Co., Ltd
